The new Liebert® EXL™ S1 is a monolithic, transformer-free UPS that features optimized, industry leading footprint and power per square foot, excellent operating efficiency, robust electrical protection and intelligent paralleling that optimizes performance at partial load to achieve superior cost savings. Available in single module and distributed bypass configurations. Compatible with lithium ion battery systems.
?
OPTIONAL I/O CABINET
INTERNAL VIEW
FRONT VIEW
PRODUCT
x
LOW TCO obtained with 97% efficiency in double conversion mode and 99% in ECO mode. Small footprint allows more beneficial use of space.
TAP or CLICK the highlighted areas to view more information.
COMMUNICATION CABLES can enter the top or bottom of the UPS. Connection area is recessed below an acrylic cover so all cables are below the top panel skin. No front access is required. No requirement to go into bypass or shutdown power to access this area.
Liebert® EXL™ S1
TOUCHSCREEN CONTROL PANEL is intuitive to use, consistent with other Vertiv touchscreens, has customer configurable data and views, multiple user security levels and Status-At-A-Glance LED light.
STANDARD INPUT / OUTPUT cabinet offers top or bottom cable entry and optional single input jumpers.
Front View
HIGHEST POWER DENSITY available for this size kVA rating, leading to the most compact UPS footprint in the market.
>
FRONT VIEW DETAILS
Zoom
Double click on model or scroll anywhere or Pinch (touch)
Pan
Right click + drag or
Two fingers drag (touch)
INTERNAL VIEW
Orbit around
Left click + drag or
One finger drag (touch)
Optional DC BATTERY GROUND FAULT DETECTION for 2014 NEC compliance enables the detection and annunciation of battery DC ground faults.
BFD and SI
CMC and BFD
Back Feed Disconnect(BFD)
CMC and SI
OPTIONAL I/O CABINET
CMC, BFD and SI
Back Feed Disconnectect
Optional BACK FEED DISCONNECT (BFD) isolates back feed voltage from the upstream source, eliminating the need for a shunt trip accessory in the external upstream back feed breaker.
Sharing Inductors (SI)
Rectifier input, bypass, output & DC bus bars accessible in a SINGLE CABINET.
Common Mode Choke (CMC)
Top or bottom CABLE ENTRY for easy and flexible installation. Copper and Aluminum cables supported.
STRATEGICALLY SPACED BUS BARS for easy cable routing and termination. Expanded DC bus bars provide additional space for battery conductor terminations.
CONTROL BOARD SECTION houses all main PCBs in a single compartment.
CONTINUOUS DUTY STATIC SWITCH with dual speed thermostatically controlled AC centrifugal fans. This robust static switch has a high overload capability and works in conjunction with Liebert EXL S1 controls to provide fast transfers (<2 ms) from ECO mode.
TAP or CLICK the highlighted areas to view more information.
RECTIFIER INPUT, bypass, output & DC bus bars accessible in a single cabinet.
Internal View
600kVA/kW POWER CORES provide the highest available power density in this size UPS. Offers double conversion efficiency up to 97%.
SINGLE INPUT JUMPERS provide simple solution to single input applications.
MONITORED DC VARIABLE SPEED FANS (100,000 hour life) provide efficient front to top cooling. Liebert EXL S1 will continue to operate at full load after a fan failure depending on temperature and loading.
INTERNAL VIEW DETAILS
TOP OR BOTTOM CABLE ENTRY for easy and flexible installation. Copper and Aluminum cables supported.
Back Feed Disconnect (BFD)
Optional SHARING INDUCTORS may be installed to ensure parallel UPS modules share the load evenly when powering the load through their static bypass switches. Some applications may require this option when it is difficult or impossible to match parallel UPS cable length
Sharing Inductors
Optional COMMON MODE CHOKE may be installed for applications that require dual asynchronous source input (i.e., applications where the rectifier and bypass input of the UPS are not fed from the same solidly grounded wye source).
Common Mode Choke
Optional SHARING INDUCTORS (located behind BFD) may be installed to ensure parallel UPS modules share the load evenly when powering the load through their static bypass switches. Some applications may require this option when it is difficult or impossible to match parallel UPS cable length.
Optional BACK FEED DISCONNECT (BFD) isolates back feed voltage from the upstream source, eliminating the need for a shunt trip accessory in the external upstream back feed breaker.
BFD and SI
Optional COMMON MODE CHOKE may be installed for applications that require dual asynchronous source input (i.e., applications where the rectifier and bypass input of the UPS are not fed from the same solidly grounded wye source).
CMC and BFD
CMC and SI
Optional SHARING INDUCTORS may be installed to ensure parallel UPS modules share the load evenly when powering the load through their static bypass switches. Some applications may require this option when it is difficult or impossible to match parallel UPS cable length.
Optional BACK FEED DISCONNECT (BFD) isolates back feed voltage from the upstream source, eliminating the need for a shunt trip accessory in the external upstream back feed breaker.
CMC, BFD and SI
Optional SHARING INDUCTORS (located behind BFD) may be installed to ensure parallel UPS modules share the load evenly when powering the load through their static bypass switches. Some applications may require this option when it is difficult or impossible to match parallel UPS cable length.